格力空调故障代码h1是化霜故障

发布时间:2019/5/23 10:21:27 浏览次数: 259

上海格力空调服务请参照以下格力故障代码

Shanghai Gree Air Conditioner Maintenance Refer to the following Gree Failure Code

故障,保护意义 显示器代码 内机指示灯显示

Failure, Protection Significance Display Code Internal Machine Indicator Display

系统高压保护 E1 运行灯 灭3S闪烁1次

System High Voltage Protection E1 Operating Lamp Turns Out 3S Scintillation One Time

内机防冻保护 E2 运行灯灭3S闪烁2次

Antifreeze Protection E2 Operating Lamp of Internal Machine Shuts off 3S and flickers twice

系统低压保护 E3 运行灯灭3S闪烁3次

System Low Voltage Protection E3 Operating Lamp Turns Out 3S Scintillation Three Times

压缩机排气保护 E4 运行灯灭3S闪烁4次

Compressor Exhaust Protection E4 Running Lamp Turns Out 3S Scintillation Four Times

低电压过流保护 E5 运行灯灭3S闪烁5次

Low Voltage Overcurrent Protection E5 Operating Lamp Turns Out 3S Scintillation Five Times

通讯故障 E6 运行灯灭3S闪烁6次

Communication failure E6 running lamp turns off 3S and flickers six times

模式冲突 E7 运行灯灭3S闪烁7次

Mode Conflict E7 Running Lamp Turns Out 3S Flicker Seven Times

防高温保护 E8 运行灯灭3S闪烁8次

High Temperature Protection E8 Operating Lamp Turns Out 3S Scintillation 8 Times

防冷风保护 E9 运行灯灭3S闪烁9次

Cold-proof wind protection E9 running lamp turns off 3S and flickers 9 times

室温开,短路 F1 制冷指示灯灭3S闪1次

Open at room temperature, short circuit F1 refrigeration indicator lights out 3S flash once

内管温开,短路 F2 制冷指示灯灭3S闪2次

Inside tube temperature open, short circuit F2 refrigeration indicator lights out 3S flash twice

外环温开,短路 F3 制冷指示灯灭3S闪3次

Outer ring temperature open, short circuit F3 refrigeration indicator lights out 3S flash 3 times

冷凝器管温开,短路 F4 制冷指示灯灭3S闪4次

Condenser tube temperature open, short circuit F4 refrigeration indicator lights out 3S flash 4 times

外排气管温开,短路 F5 制冷指示灯灭3S闪5次

Open the exhaust pipe warm, turn off the F5 short circuit refrigeration indicator 3S and Flash 5 times

化霜 H1 制热指示灯灭3S闪烁1次

Frost H1 heating indicator lights out 3S flicker once

静电除尘保护 H2 制热指示灯灭3S闪烁2次

Protection of H2 heating indicator by electrostatic precipitation

压缩机过载保护 H3 制热指示灯灭3S闪烁3次

Compressor overload protection H3 heating indicator lights out 3S flashing three times

系统异常 H4 制热指示灯灭3S闪烁4次

System abnormal H4 heating indicator lights out 3S flicker 4 times

模块保护格力空调服务 H5 制热指示灯灭3S闪烁5次

Module Protected Gree Air Conditioner Maintenance H5 Heating Indicator lights out 3S and flickers 5 times

滑动门故障 FC

Sliding door fault FC




春普上海中央空调中央从事上海新风系统,写字楼中央空调改造,中央空调改造报价办公楼中央空调

官方网站:http://www.shchunpu.com/


最新内容:
上一篇: 格力空调故障代码含义及服务方法
下一篇: 格力吸顶式空调室外机电路板(发光管闪烁)是哪里故障

©2002-2015 上海春普空调设备有限公司  All rights reserved. 备案号:沪ICP09065509号
公司邮箱:shchunpu@126.com       公司地址:浦东新区上南路3855弄11号602室
本站所有商品均提供销售,安装和维修服务。本站内所有产品以实样为准,图片仅供参考。保留最终解释权。
本公司专业从事上海中央空调上海新风系统酒店中央空调改造中央空调改造报价上海格力中央空调办公楼中央空调上海日立中央空调等的销售、设计,安装,售后服务为一体的企业

网站首页 | 关于春普 | 品牌产品 | 新闻中心 | 解决方案 | 工程案例 | 服务支持 | 方案报价 | 联系我们